GWDL 500°C Atmosphere Rotary Furnace Technical Specifications
| Temperature | Design temperature 500°C |
|---|---|
| Model | GWL-500 |
| Voltage AC | 380V±10% |
| Floor space | 3700mm1000mm1700mm |
| Power | 50KW |
| Furnace tube | Outer diameter 210mm, wall thickness 6mm, total length 3200mm. The furnace tube is rolled, butt-welded with the same material, and the inner surface is polished. Spiral augers are welded at both ends of the furnace tube over 200-300mm. Material-lifting plates are welded at three equally spaced positions around the circumference in the middle section, and the lifting plates in each temperature zone are staggered. Furnace tube material: AT2. |
| Heating length / Temperature control zones | Heating length 2100mm. 3 independently controlled temperature zones, effectively ensuring furnace tube uniformity. 3 temperature-control thermocouples, 3 temperature-measurement thermocouples, 6 in total. |
| Nickel-chromium/nickel-silicon type K, measurement range 0-1350°C. Temperature control accuracy: ±1°C. Temperature field uniformity inside the furnace: ±5°C (depending on the size of the heating chamber). | |
| Feeding | Screw feeding adopted, with an anti-jamming device. |
| Screw feeder screw material | Titanium alloy (TA10) |
| Inlet/outlet tank structure | Inlet/outlet tanks: one feed tank and one transition tank respectively. A double-valve isolation is provided between the two tanks. Inlet/outlet port size: KF40. A visible observation port is added. Flanges and inlet/outlet tanks are made of 316L material. Tank: maximum Φ300*300mm, volume greater than 20L. |
| Furnace tube heat tracing | Heat tracing device is added to the lower feed bin at 300°C. Heat tracing devices are added at both ends of the furnace tube at 150°C. |
| Furnace body tilting / Furnace cover opening | Electric hydraulic push rod for convenient maintenance. |
| Furnace tube rotation speed | 0.3~3 r/min, continuously adjustable. Furnace body tilting angle: 0-3°, adjustable. |
| Touch screen operation | 10-inch true-color touch screen for centralized control, with functions including heating setting, historical curves, data reports, alarm information, humidity value display, power percentage, etc. |
| Heating elements | High-temperature alloy resistance wire (imported Kanthal A1) |
| Heating element position | Installed around the furnace tube. |
| Heating rate | 0-10°C/min |
| Furnace body | The furnace body is machined by CNC machine tools and manufactured through processes including polishing, grinding, pickling, phosphating, powder coating, and high-temperature baking. It has a novel and attractive appearance and offers advantages such as oxidation resistance, acid and alkali resistance, corrosion resistance, high-temperature resistance, and easy cleaning. |
| Furnace body structure | The electric furnace body adopts an air-cooled double-layer furnace body structure. An effective air-cooled guide baffle enables overall cold air circulation in the furnace shell, ultimately cooling the conductive plates of the heating elements before discharging from the furnace body, thereby avoiding high-temperature oxidation of the conductive plates of the heating elements; ensuring a good working environment. |
| Insulation material | Three-layer insulation is adopted: aluminosilicate fiber board, alumina fiber board, and alumina (polycrystalline) fiber board. |
| Furnace outer shell temperature | For long-term continuous operation without shutdown, the outer shell temperature is room temperature +25°C. |
| Protection | An integrated modular control unit is adopted, with accurate control precision. Dual-loop control and dual-loop protection are designed, with protections including overshoot, over-adjustment, under-adjustment, thermocouple break, phase loss, overvoltage, overcurrent, overtemperature, current feedback, soft start, etc. |
| Control | Closed-loop technology is adopted with SCR module trigger control and phase-shift trigger control mode. Output voltage, current, or power is continuously adjustable, with characteristics of constant voltage, constant current, or constant power. The current loop is the inner loop and the voltage loop is the outer loop. When load is suddenly applied or the load current exceeds the current limit value, the output current of the voltage regulator is limited within the rated current range, ensuring normal operation of the output and the voltage regulator. At the same time, the voltage loop also participates in regulation, so that the output current of the voltage regulator is limited within the rated current range, maintaining constant output current and voltage under the premise of sufficient regulation margin. This protects the heating elements from impact of excessive current and voltage and achieves safe and reliable control effects and control precision. |
| Temperature curve setting | Intelligent temperature controllers are adopted, with multiple regulation modes such as standard PID, artificial intelligence regulation APID, or MPT. They have self-tuning and self-learning functions and excellent control characteristics of no overshoot and no undershoot. They are equipped with 30-segment program control functions, enabling heating and cooling control at any slope, with programmable/operable commands such as jump (cycle), run, pause, and stop, and allow the program to be modified at any time during program-controlled operation. An artificial intelligence regulation algorithm with curve fitting function is adopted to obtain smooth and stable curve control effects. |
| Multiple curve input | 30-segment program control function, which can be input and set as follows: one curve with 30 segments, two curves with 14 segments each, three curves with 9 segments each, or five curves with 5 segments each. Multiple curves can be input simultaneously and can be called arbitrarily during use. |
| Exhaust port | One exhaust port DN32 with valve is reserved at the upper end of the inlet-end cover. |
| Warranty scope and period | The electric furnace has a free warranty of one year. Heating elements and furnace tubes are not covered by warranty (heating elements naturally damaged within three months will be replaced or repaired free of charge). |
| Random spare parts | One copy of the instruction manual, one certificate of conformity, one pair of crucible tongs, one pair of high-temperature gloves, and two sets of sealing rings. |
| Shipping matters | 1. The electric furnace is packaged in two layers: wrapped with sponge paper, then wrapped with plastic film, and then fixed with an iron frame as a base support. |
| Vacuum pumping system | Extracts air from the furnace chamber to ensure atmosphere purity. |
| Flow meter | Mass flow meter: range 0~25 SLM, one set each for hydrogen sulfide and nitrogen gas lines. |
| Notes | British-style 1/4 connectors are adopted. For exposed pipelines, feed bins, discharge bins, and other uninsulated areas, bellows compensation structures and heat tracing systems are used to avoid condensation. |
Control Part
| Main rotation and tilting control | Touch screen and Siemens PLC control word |
|---|---|
| Control | |
| Power supply parameters | 3P AC380V / 50HZ +N+PE |
| Appearance color | RAL color card 7035# |
| Digital temperature controller | 858X series, 3 units, 0-1300°C PID continuous temperature control (with RS-485 communication interface) |
Gas Preheating System
| Gas preheating furnace design temperature | Greater than 500°C / 8KW |
|---|---|
| Heating rate | 15°C/min |
| Temperature control | Program temperature control, equipped with a 7-inch touch screen |
| Furnace tube size | Diameter 1/4 |
| Heating zone length | Diameter 90*300 |
| Heating element | Resistance wire |
| Coil material | 310S stainless steel tube |
| Gas mixing tank | Equipped with a 30L gas mixing tank |
| Insulation method for connection between outlet pipeline and flange | Heat tracing cable |
| Remarks | The preheating system is integrated into the lower part of the electric furnace. |